Call Us+919137820984
Methane Detector

Methane Detector

8000.00 - 16000.00 INR/Piece

Product Details:

  • Material Cast Aluminium alloy, LM-6
  • Power Supply 18 to 36 VDC; Typical 24 VDC .
  • Power Consumption Less than 3.6 Watt (W)
  • Accuracy On Full Scale ± 2 %
  • Display Type Digital Only
  • Supply Ability : 300 Piece Per Day
  • Click to view more
X

Price And Quantity

  • 8000.00 - 16000.00 INR/Piece
  • 1 Piece

Product Specifications

  • Digital Only
  • Less than 3.6 Watt (W)
  • Cast Aluminium alloy, LM-6
  • 18 to 36 VDC; Typical 24 VDC .
  • On Full Scale ± 2 %

Trade Information

  • 300 Piece Per Day
  • 1 Week
  • All India
  • Protection Class : IP-66 for Gas Gr. IIA, IIB & CMRI approved enclosure, CCOE (Optional)

Product Description

 

Features

  • Provides a fast and reliable output by using Electro Chemical / Pellister Sensor Technology.
  • Optimized for detection of smallest leak of Oxygen, Toxic and Combustible Gases.
  • Highly resistant to poisoning and etching.
  • Capable of detecting down to PPM, %LEL & %V/V.
  • Digital display of Gas Concentration on LCD Display
  • Standard 4-20mA signal output with configurable range.
  • Easy handling and programming with 3 keys for Weatherproof Models.
  • Non - Intrusive programming for Flameproof model using Magnetic pen.
  • Password protected programming with password changing facility.
  • One man Auto Software Gas Calibration.
  • Optional Alarm relay contacts with two configurable Alarm levels & one Relay for fail safe Operation.
  • Optional STEL and TWA set points can be configured for Toxic Gases.
  • Optional RS-485 communication port with MODBUS RTU Protocol.

Approval & Compliance

 

Approval & Compliance for Flameproof :

Certified to Ex-d IIA, IIB, T6, IP66 Compliance with :

IS/IEC 60079-0 : 2004  IS/IEC 60079-1: 2007  IS/IEC 60529 : 2001

CE Mark :

Conforms with essential requirement of :

  • Electromagnetic Compatibility Directive 2014/30/EU,
  • Low voltage Directive 2014/35/EU
  • EN 50270:2006
  • Compliance with the IEC 60945 Standard for Marine application

Applications

  • Gas Metering skid
  • Gas Metering Station
  • Gas Cylinder Bank
  • Burner / Furnace Areas
  • Oil & Gas Industries
  • Bullet Yard / Storage Yard
  • Gas Pipeline Project
  • Chemical Processing Plant
  • Acid Alkalizes & Dyes Mfg. Plants
  • Refineries
  • Offshore Drilling & Processing Platforms
  • Cold Storage
  • Heat Treatment Plants
  • Sewage Plants
  • Chemical Storage Area
  • Fertilizers Plants
  • Control Atmosphere
  • Stack Monitoring
  • Power & Industrial Plants
  • Chlorination Plant
  • Coal Mine and Confined Area
  • Ambient Monitoring
  • Chemical & Petrochemical Plants
  • Pulp & Paper Plants
  • Automotive Industries / Paint Shops

Technical Specifications

General :


Detection Method

Electrochemical / Catalytic Bead / Pellistor / Siegistor

Gases Detected

Oxygen / Toxic / Combustible (Please select from the table below).

Display

8x2 Alphanumeric LCD Display with Backlit & 8 LEDs to indicate status of instrument

Control Action

ii) Two independent Alarm set points with Latch &
Non-latch facility.
ii) User selectable Hysteresis and Logic option.
iii) Configurable STEL and TWA set points for Toxic Gases (optional).

Setting

By using Push button keys on Weatherproof model
By using Magnetic pen for Flameproof model

Performance


Accuracy

2% of Full Scale.

Response Time

For response , contact to factory

Start-up Time

Less than 30 Seconds.

Electrical :


Supply Voltage

18 to 36 VDC, Typically 24VDC

Power Consumption:

Less than 3.6 Watts

Supply Current

150 mA at 24 VDC

Cable

3 Wires (1.5mm2) Flexible or Armoured Shielded Cable

Weatherproof Housing :

Protection Class

IP-65

Cabinet Material

Polycarbonate, grey colour

Cable Entry

Thermoplastic cable gland (IP 68)

Dimension

170mm(H) x 100mm(W) x 60mm(D) (with 1 Gland)

170mm(H) x 120mm(W) x 60mm(D) (with 2 Glands)

Mounting

Wall Mounting / Stand Mounting / Pipe Mounting

Weight

Approx 500 Grams

Output Signal :

Standard

4-20mA Current Output with configurable range selection

with 470 ohm load driving capacity.

Optional

Three SPDT Relays (one for Fail Safe and Two for

Alarm indication) of rating 2A/120VAC, 2A/24VDC

Optional

RS-485 Communication port with MODBUS RTU protocol.

Error Monitoring :

During Sensor Break / Open, the Display shows SENSOR OPEN & 4-20mA output goes down to 3.7mA for Combustible gases only.

During Over range, the Display shows OVER RANGE & 4-20mA output goes up to 21mA

Environmental :

  • Operating Temperature: -15°C to +55oC
  • Storage Temperature: -20 to +60oC
  • Humidity: Less than 95% Non-Condensing.

Accessories (Optional) :

  • CE certified 24 VDC Power supply.
  • Gas Sampling & Conditioning System.
  • Canopy & Mounting stand.
  • RS-485 to USB OR RS-232 convertor
  • Gas Calibration Kit (0.5,1, 3,10)Liter.
  • PC Based SCADA Software, Modem
  • Hooter Cum Flasher.

Flameproof Housing :

Protection Class

IP-66 for Gas Gr. IIA, IIB & IIC, CMRI (CIMFR) tested Enclosure, CCOE (Optional).

Cabinet Material

Cast Aluminium alloy, LM-6

Cable Entry

Double compression cable gland (EX-Proof), 3/4 ET-type

Dimension

185mm(H) x 215mm(W) x 125mm(D) (with 1 Gland)


185mm(H) x 260mm(W) x 125mm(D) (with 2 Glands)

Mounting

Wall Mounting / Stand Mounting / Pipe Mounting

Weight

Approx 2 Kg.


AMBETRONICS ENGINEERS PVT. LTD.

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Back to top
AMBETRONICS ENGINEERS PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.